CO₂ Fire Extinguisher – 3 KG & 5 KG | Electrical and Flammable Liquid Fire Protection

Price range: ₨8,000 through ₨11,500

The Fire Titan CO₂ Fire Extinguisher is designed for fires involving energised electrical equipment and flammable liquids. Available in 3 KG and 5 KG capacities, it releases carbon dioxide without leaving powder, foam or liquid residue behind.

SKU: 001 Category: Brand: Product ID: 2382

Description

The Fire Titan CO₂ Fire Extinguisher provides fast, clean fire suppression for areas containing electrical equipment, machinery and flammable liquids.

Carbon dioxide is a colourless, non-flammable and electrically non-conductive gas. It suppresses fire mainly by reducing the oxygen concentration and fuel vapour around the flames. This makes CO₂ especially useful around electrical installations where water-based extinguishers would create an electrical hazard.

Unlike dry powder or foam extinguishers, CO₂ does not leave a significant extinguishing-agent residue. This helps reduce cleanup around sensitive equipment, although fire or heat itself may still damage electronic devices.

The extinguisher is available in two capacities:

  • 3 KG for smaller commercial and electrical-risk areas
  • 5 KG for larger premises requiring greater extinguishing capacity

The correct size, fire rating and number of extinguishers should be selected through a professional fire-risk assessment.

Available Capacities

CO₂ Fire Extinguisher – 3 KG

The 3 KG CO₂ Fire Extinguisher provides compact and portable protection for smaller electrical and commercial environments.

Recommended Applications

  • Small offices
  • Server and network rooms
  • Computer rooms
  • Electrical panels
  • Laboratories
  • Retail stores
  • Workshops
  • Generator control areas
  • Small machinery rooms

The 3 KG model is easier to carry and position in locations where space is limited.

CO₂ Fire Extinguisher – 5 KG

The 5 KG CO₂ Fire Extinguisher contains a larger volume of extinguishing agent and is suitable for higher-risk commercial and industrial settings.

Recommended Applications

  • Large server rooms
  • Factories
  • Industrial workshops
  • Electrical substations
  • Generator rooms
  • Commercial kitchens for electrical risks only
  • Warehouses
  • Manufacturing facilities
  • Machinery and control rooms
  • Petrol and fuel-handling areas

The 5 KG model may provide longer discharge and greater fire-fighting potential, but the exact performance must be confirmed from the actual product rating and manufacturer’s datasheet.

Capacity Comparison

CapacityRecommended UsePortability
3 KGOffices, server rooms, panels and smaller electrical areasEasier to carry
5 KGFactories, workshops, substations and larger risk areasLarger commercial unit

Key Features

  • Available in 3 KG and 5 KG capacities
  • Suitable for electrical and flammable-liquid fire risks
  • Electrically non-conductive extinguishing agent
  • Leaves no powder or foam residue
  • Suitable around sensitive machinery and equipment
  • Strong discharge horn for controlled application
  • Safety pin and operating lever
  • Durable red cylinder
  • Easy-to-identify black CO₂ label section
  • Portable and straightforward to operate
  • Professional inspection and refilling support available

Suitable Fire Risks

Energised Electrical Equipment

CO₂ extinguishers are particularly suitable for fires involving electrical equipment because carbon dioxide is electrically non-conductive. Official fire-safety guidance commonly recommends CO₂ for electrical risks.

Examples include:

  • Computers
  • Electrical panels
  • Switchboards
  • Servers
  • Generators
  • Motors
  • Machinery
  • Telecommunications equipment
  • Laboratory equipment

Whenever possible, disconnect the electrical supply when it is safe to do so.

Flammable-Liquid Fires

An appropriately rated CO₂ extinguisher may also be used on certain fires involving:

  • Petrol
  • Diesel
  • Paint
  • Solvents
  • Oils
  • Selected industrial liquids

CO₂ is recognised for applications involving flammable-liquid and electrical hazards.

Do Not Use On

A CO₂ extinguisher should not normally be used as the main extinguisher for:

  • Wood, paper and textile fires
  • Deep-seated Class A fires
  • Cooking oils and deep-fat fryers
  • Flammable-gas leaks
  • Combustible-metal fires
  • Fires in confined spaces without proper safety controls
  • Fires that are already large or spreading rapidly

CO₂ has limited cooling effect compared with water-based extinguishers, so some materials may reignite after the visible flames disappear.

Important CO₂ Safety Warnings

Risk in Confined Spaces

Carbon dioxide displaces oxygen. A high concentration can create a serious breathing or suffocation hazard, particularly in small or poorly ventilated areas.

Do not remain in an enclosed area after discharging a CO₂ extinguisher. Evacuate and ventilate the area when safe.

Extremely Cold Discharge

The discharge horn and nearby metal components can become extremely cold during use.

  • Hold only the insulated handle provided.
  • Do not touch the horn during or immediately after discharge.
  • Avoid directing the discharge toward people.
  • Do not place any part of the body directly in front of the horn.

How to Use a CO₂ Fire Extinguisher

Only attempt to use the extinguisher when:

  • The alarm has been raised.
  • The fire is small and contained.
  • You have a clear escape route.
  • The extinguisher is suitable for the fire.
  • Smoke and heat are not making the area unsafe.

Follow These Steps

1. Pull

Pull out the safety pin and break the tamper seal.

2. Position the Horn

Hold the insulated horn handle and point it toward the base of the fire.

3. Squeeze

Squeeze the operating lever to release the carbon dioxide.

4. Sweep

Move the horn carefully from side to side across the base of the flames.

Stop and evacuate immediately when the fire grows, visibility becomes poor or your escape route is threatened.

Product Specifications

SpecificationDetails
Product NameCO₂ Fire Extinguisher
Full NameCarbon Dioxide Fire Extinguisher
BrandFire Titan
Available Capacities3 KG and 5 KG
Extinguishing AgentCarbon dioxide
Typical Fire ApplicationsElectrical and flammable-liquid fires
Electrical ConductivityNon-conductive extinguishing medium
ResidueNo powder, foam or water residue
Discharge OutletCO₂ horn
Cylinder ColourRed
Identification ColourBlack label section
Operating TypePortable and manually operated
InstallationWall bracket or designated fire point
InspectionProfessional inspection recommended
RefillingRequired after partial or complete discharge

Specifications to Confirm Before Publishing

Obtain these details from the supplier or product datasheet:

  • Exact fire rating
  • Working pressure
  • Test pressure
  • Discharge duration
  • Discharge range
  • Cylinder dimensions
  • Filled weight
  • Valve material
  • Horn construction
  • Operating temperature
  • Manufacturing standard
  • Certification
  • Warranty

Maintenance and Inspection

To keep the extinguisher ready for emergency use:

  • Keep it visible and accessible.
  • Make sure the safety pin and tamper seal are intact.
  • Inspect the cylinder for corrosion, dents or damage.
  • Check that the horn and hose are properly attached.
  • Confirm that operating instructions remain readable.
  • Do not place the extinguisher close to extreme heat.
  • Arrange scheduled inspection by a trained technician.
  • Refill or replace it immediately after any discharge.
  • Have the cylinder weighed during servicing because many CO₂ extinguishers do not use a standard pressure gauge.

Why Choose Fire Titan?

  • Available in practical 3 KG and 5 KG capacities
  • Suitable for electrical and commercial fire risks
  • Clean extinguishing agent with no powder residue
  • Professional product-selection guidance
  • Installation and placement support
  • Inspection, maintenance and refilling services
  • Fire-safety solutions for commercial and industrial properties
  • Competitive quotations across Pakistan

Frequently Asked Questions

What is a CO₂ fire extinguisher used for?

It is commonly used for fires involving energised electrical equipment and certain flammable liquids.

Does a CO₂ extinguisher damage electrical equipment?

CO₂ does not leave powder, water or foam residue, which makes it suitable around many electrical devices. However, the fire, heat or very cold discharge may still damage sensitive equipment.

Which size should I choose?

The 3 KG model is suitable for smaller electrical and commercial areas. The 5 KG model is generally more appropriate for larger machinery rooms, factories and industrial locations.

Can it be used on wood or paper fires?

It is not the preferred choice because these materials can retain heat and reignite. A suitable water or foam extinguisher may be required for ordinary Class A materials.

Can it be used on cooking-oil fires?

No. Use an approved wet chemical extinguisher for cooking oils and deep-fat fryer fires.

Does it leave residue?

No significant extinguishing-agent residue is left behind after CO₂ discharge.

Why does a CO₂ extinguisher have a large horn?

The horn directs the rapidly expanding carbon dioxide toward the fire. It must only be held by its insulated grip because it can become extremely cold.

Does it need refilling after use?

Yes. Any partially or fully discharged extinguisher must be inspected and professionally refilled or replaced.

Additional information

Size

3 KG, 5 KG

Reviews

There are no reviews yet.

Be the first to review “CO₂ Fire Extinguisher – 3 KG & 5 KG | Electrical and Flammable Liquid Fire Protection”

Your email address will not be published. Required fields are marked *

0
0
Your Cart
Empty CartYour cart is emptyReturn to Shop
Secure Checkout
Fast Shipping
Easy Returns