ABC Dry Chemical Powder Fire Extinguisher in Pakistan – 1 KG, 2 KG & 6 KG

Price range: ₨2,000 through ₨4,500

The Fire Titan DCP Fire Extinguisher is a versatile, multipurpose fire extinguisher available in 1 KG, 2 KG and 6 KG capacities. It uses dry chemical powder to control fires involving ordinary combustible materials, flammable liquids, flammable gases and certain energised electrical equipment where the extinguisher is appropriately rated.

SKU: 002 Category: Brand: Product ID: 2381

Description

Multipurpose Fire Protection for Different Environments

The Fire Titan DCP Fire Extinguisher, also known as an ABC Dry Powder Fire Extinguisher, provides fast and effective first-response protection against several common fire risks.

It contains a dry chemical extinguishing agent that helps suppress fire by interrupting the chemical reaction and separating the burning material from oxygen. Multipurpose ABC powder commonly uses monoammonium phosphate and is designed for Class A, B and C fire risks, depending on the extinguisher’s certification and rating.

The extinguisher is available in three practical capacities:

  • 1 KG for compact and portable protection
  • 2 KG for vehicles and small commercial spaces
  • 6 KG for larger commercial and industrial environments

Its red cylinder, pressure gauge, safety pin, operating lever and clearly displayed instructions make it easy to identify and inspect. The correct capacity and quantity should always be selected according to the property’s fire-risk assessment.

Available Capacities

DCP Fire Extinguisher – 1 KG

The 1 KG DCP Fire Extinguisher is compact, lightweight and easy to store. It is suitable for locations where space is limited and quick access to basic fire protection is required.

Recommended Applications

  • Cars and small vehicles
  • Small offices
  • Security cabins
  • Residential kitchens for non-cooking-oil risks
  • Small shops
  • Electrical control areas
  • Personal workspaces

The 1 KG model provides portable emergency protection but should not be treated as a substitute for larger extinguishers where the identified fire risk requires greater capacity.

DCP Fire Extinguisher – 2 KG

The 2 KG DCP Fire Extinguisher offers more extinguishing agent than the compact 1 KG version while remaining easy to carry and install.

Recommended Applications

  • Cars, vans and commercial vehicles
  • Small workshops
  • Retail shops
  • Small offices
  • Generator areas
  • Garages
  • Residential properties
  • Small storage rooms

This capacity is a practical choice where portability and improved fire-fighting duration are both important.

DCP Fire Extinguisher – 6 KG

The 6 KG DCP Fire Extinguisher is designed for larger or higher-risk environments. Its increased powder capacity makes it more suitable for commercial and industrial fire-safety arrangements.

Recommended Applications

  • Offices
  • Warehouses
  • Factories
  • Workshops
  • Commercial buildings
  • Petrol and fuel-related areas
  • Generator rooms
  • Parking areas
  • Construction sites
  • Industrial facilities

The 6 KG model is commonly selected for premises containing a combination of ordinary combustible materials, flammable liquids, gases and electrical equipment. Final placement and quantity should be based on a professional fire-risk assessment.

Capacity Comparison

CapacityBest Suited ForPortability
1 KGCars, small rooms and limited spacesVery easy to carry
2 KGVehicles, shops, garages and small officesEasy to carry
6 KGOffices, workshops, warehouses and industrial premisesLarger commercial unit

These application suggestions are general guidance. Actual extinguisher selection should consider the hazard, fire rating, travel distance, room size and applicable safety requirements.

Key Features

  • Available in 1 KG, 2 KG and 6 KG capacities
  • Multipurpose dry chemical powder
  • Designed for several common fire risks
  • Fast fire-suppression action
  • Suitable for portable emergency use
  • Pressure gauge for routine visual checks
  • Clearly marked operating instructions
  • Safety pin and tamper seal
  • Durable red steel cylinder
  • Corrosion-resistant external finish
  • Easy to mount at a designated fire point
  • Inspection, maintenance and refilling support available

Suitable Fire Risks

A multipurpose ABC DCP extinguisher may be suitable for:

Class A Fires

Fires involving ordinary solid combustible materials, including:

  • Wood
  • Paper
  • Cardboard
  • Textiles
  • Fabrics
  • Selected plastics

Class B Fires

Fires involving flammable liquids, including:

  • Petrol
  • Diesel
  • Paint
  • Solvents
  • Oils
  • Certain chemicals

Class C Fires

Under the fire-class system commonly used in Pakistan and many international markets, Class C refers to flammable gases, such as:

  • LPG
  • Propane
  • Butane
  • Natural gas

Electrical Equipment

Dry powder is electrically non-conductive and may be used on certain fires involving energised electrical equipment where the product label and certification permit it. The electrical supply should be isolated as soon as it is safe to do so.

Important Usage Limitations

Do Not Use On

A standard ABC DCP extinguisher should not be presented as suitable for:

  • Cooking oil and deep-fat fryer fires
  • Class F kitchen fires
  • Combustible-metal fires unless it contains specialist Class D powder
  • Fires too large to control safely
  • Situations where smoke, heat or flames block the escape route

Standard ABC powder and specialist Class D powder are different products. A general DCP extinguisher must not be described as suitable for magnesium, sodium, aluminium powder or other combustible-metal fires unless its certification specifically states this.

Important Indoor Safety Note

Dry powder can reduce visibility, irritate breathing and leave extensive residue after discharge. For this reason, it may not be the preferred extinguisher for small, crowded or poorly ventilated indoor environments.

CO₂ or another suitable clean-agent extinguisher may be more appropriate around sensitive electronics, depending on the identified fire risk.

How to Use the DCP Fire Extinguisher

Only attempt to control a fire when:

  • The alarm has already been raised.
  • The fire is still small and contained.
  • You have the correct extinguisher.
  • You have a clear escape route.
  • Smoke and heat are not creating an immediate danger.

Follow the PASS Method

1. Pull

Pull the safety pin and break the tamper seal.

2. Aim

Aim the hose or nozzle at the base of the flames.

3. Squeeze

Squeeze the operating handles to release the powder.

4. Sweep

Sweep the discharge from side to side across the fire.

For a flammable-liquid fire, avoid directing the powder with enough force to splash or spread the burning liquid.

Evacuate immediately when the fire continues to grow, the extinguisher becomes empty or your escape route becomes unsafe.

Product Specifications

SpecificationDetails
Product NameDCP Fire Extinguisher
Full TypeDry Chemical Powder Fire Extinguisher
BrandFire Titan
Available Capacities1 KG, 2 KG and 6 KG
Extinguishing AgentMultipurpose dry chemical powder
Typical Powder TypeABC powder
Typical Fire ClassesClass A, B and C
Electrical UseOnly where marked and appropriately rated
Cylinder ColourRed
Operating TypePortable and manually operated
Discharge SystemHose/nozzle depending on capacity
InstallationVehicle bracket or designated fire point
MaintenanceProfessional inspection recommended
RefillingRequired after any partial or complete discharge

Specifications to Confirm Before Publishing

The following information must come from the actual manufacturer or supplier datasheet:

  • Exact fire rating
  • Percentage and composition of powder
  • Working pressure
  • Test pressure
  • Discharge time
  • Discharge range
  • Filled weight
  • Operating temperature
  • Cylinder dimensions
  • Cylinder material and thickness
  • Valve material
  • Certification or approval
  • Manufacturing standard
  • Warranty period
  • Electrical voltage and safe-distance rating

Do not add estimated values because specifications can differ between 1 KG, 2 KG and 6 KG models.

Maintenance and Inspection

To keep the extinguisher ready for use:

  • Keep it visible and unobstructed.
  • Confirm that the safety pin and tamper seal remain intact.
  • Check that the pressure-gauge needle is within the operating range.
  • Inspect the cylinder for rust, dents, leakage or damage.
  • Check the hose and nozzle for blockage or deterioration.
  • Ensure the operating instructions remain readable.
  • Arrange periodic professional inspection and servicing.
  • Refill or replace the extinguisher after any discharge.
  • Follow the manufacturer’s maintenance instructions.

Dry chemical powder can compact over time, so servicing should be completed by a qualified fire-safety technician.

Why Choose Fire Titan?

  • Multiple capacities for different requirements
  • Reliable fire-safety product selection
  • Professional installation support
  • Fire-extinguisher inspection and maintenance
  • Refilling services
  • Solutions for vehicles, homes and businesses
  • Support for commercial and industrial properties
  • Competitive quotations across Pakistan

Frequently Asked Questions

What does DCP mean?

DCP stands for Dry Chemical Powder. It is an extinguishing agent used to interrupt the fire’s chemical reaction and suppress several common types of fire.

Is DCP the same as an ABC powder extinguisher?

A multipurpose DCP extinguisher is commonly called an ABC Dry Powder Extinguisher when it is rated for Class A, B and C fires. The actual rating should always be confirmed from the cylinder label.

Which capacity should I choose?

The 1 KG model is suitable for compact applications, the 2 KG model provides greater protection for vehicles and small premises, and the 6 KG model is generally more appropriate for commercial and industrial environments.

The final selection should be based on a fire-risk assessment rather than capacity alone.

Can a DCP extinguisher be used on an electrical fire?

It may be used around certain energised electrical equipment when the product is properly tested, marked and rated for that application. Disconnect the power supply when it is safe to do so.

Can it be used on cooking-oil fires?

No. A wet chemical extinguisher designed for Class F fires should normally be used for burning cooking oils and fats.

Can it be used on combustible-metal fires?

Not unless the extinguisher contains specialist Class D powder and is specifically approved for that metal risk.

Does it leave residue?

Yes. Dry powder can spread widely and may damage or contaminate sensitive machinery and electronic equipment.

Does it need refilling after use?

Yes. Even a partly discharged extinguisher must be professionally inspected and refilled or replaced.

Additional information

Size

1 KG, 2 KG, 6 KG

Reviews

There are no reviews yet.

Be the first to review “ABC Dry Chemical Powder Fire Extinguisher in Pakistan – 1 KG, 2 KG & 6 KG”

Your email address will not be published. Required fields are marked *

0
0
Your Cart
Empty CartYour cart is emptyReturn to Shop
Secure Checkout
Fast Shipping
Easy Returns